LITHOS 5
                            
                             
	Pre-insulated metal panels with mineral fiber insulation for roofs (also available in the version with perforated internal support).
	Dimensions
	width mm 1000
	length upon request from continuous production process.
	Standard insulating thickness
	mm 50 - 60 - 80 - 100 - 120 - 150 - 200 panels of non standard thicknesses can be supplied upon request previous agreement on minimum quantities.
	Supports
	galvanized steel, galvanized prepainted or plastified steel; stainless steel; natural or prepainted aluminium; copper (CORAM).
	Isulation
	made by a special configuration insulating layer, in high-density mineral fibers (λ = 0,040 W/mK), arranged perpendicular to the plate plane.
	Protective treatments for external support available
	On request for external polyester coating, atoxic prepainted for food contact, silicone polyester, PVDF, thermoplastic Class A application of PVC plastic films or other films.
	EPD certification (CAM)
	The entire range of roofing and wall panels in steel and aluminium in PIR, PUR and mineral wool, single metal sheet panels and corrugated metal sheets in steel and aluminium, possess the EPD type III - EN ISO 14025 certification, meeting the requirements of compliance with the regulation construction DM 23 June 2022, and satisfying the required CAM criteria.
	Mod. EVO joint
	Last generation joint in the ECOLINE family, by its very rigid nature and with a high thermal break, does not require special plastic joints to hold the sheets, since the monolithicity is guaranteed by the perfect adhesion obtained with exclusive patented technologies. In particularly critical situations, a simple expanded gasket is used.
	Reaction to fire
	A2,s1-d0 - on normal unperforated panel, drilling does not allow this classification.
	 
	
		
			| 
				Available on request | 
		
		
			| 
				high density mineral fibers | 
		
		
			| 
				MODELLO / MODEL | 
			
				SPESSORE / THICKNESS | 
			
				RISULTATO / RESULT | 
			
				CLASSE / RATE | 
		
		
			| 
				Lithos | 
			
				50 | 
			
				REI30 | 
			
				A2-s1,d0 | 
		
		
			| 
				Lithos | 
			
				80 | 
			
				REI60 | 
			
				A2-s1,d0 | 
		
		
			| 
				Lithos | 
			
				100 | 
			
				REI120 | 
			
				A2-s1,d0 | 
		
		
			| 
				Lithos (Micro perforated) | 
			
				150 | 
			
				REI120 | 
			
				- | 
		
	
	Fire behavior from outside
	 BROOF (EN 13501-1)
	Fire behavior from outside for roofs
	CWFT (ENV 1187)
                             
                                
                             
                             
                             
                                 LOADS TABLE
                             
                                 
                                     PITCH BETWEEN SUPP.(m)
                                 PANEL TICKNESS(mm)
                                 SHEET TICKNESS(mm)
                                 MATERIAL
                                  
                                      | MAXIMUM UNIFORMLY DISTRIBUTED LOAD (daN/m2) - DEFLECTION * | 
|---|
Panel  Thickness (mm) | Material | Sheet  thickness (mm) | Pitch 'L' in meters between the supports | 
|---|
  | 
| 2,00 | 
2,50 | 
3,00 | 
3,50 | 
4,00 | 
4,50 | 
5,00 | 
5,50 | 
6,00 | 
|---|
| 50 | ACCIAIO | 0,6 + 0,5 | 	
164 | 	
105 | 	
73 | 	
54 | 	
41 | 	
32 | 	
26 | 	
22 | 	
18 | 
| 60 | ACCIAIO | 0,6 + 0,5 | 	
192 | 	
123 | 	
85 | 	
63 | 	
48 | 	
38 | 	
31 | 	
25 | 	
21 | 
| 80 | ACCIAIO | 0,6 + 0,5 | 	
363 | 	
232 | 	
161 | 	
119 | 	
91 | 	
72 | 	
58 | 	
48 | 	
40 | 
| 100 | ACCIAIO | 0,6 + 0,5 | 	
404 | 	
323 | 	
224 | 	
165 | 	
126 | 	
100 | 	
81 | 	
67 | 	
56 | 
| 120 | ACCIAIO | 0,6 + 0,5 | 	
438 | 	
351 | 	
265 | 	
195 | 	
149 | 	
118 | 	
96 | 	
79 | 	
66 | 
| 150 | ACCIAIO | 0,6 + 0,5 | 	
460 | 	
370 | 	
284 | 	
215 | 	
161 | 	
127 | 	
100 | 	
83 | 	
69 | 
| 200 | ACCIAIO | 0,6 + 0,5 | 	
465 | 	
375 | 	
290 | 	
220 | 	
169 | 	
149 | 	
112 | 	
94 | 	
82 | 
                                      
                                 
                                     
                                  | MAXIMUM UNIFORMLY DISTRIBUTED LOAD (daN/m2) - DEFLECTION * | 
|---|
Panel  Thickness (mm) | Material | Sheet  thickness (mm) | Pitch 'L' in meters between the supports | 
|---|
  | 
| 2,00 | 
2,50 | 
3,00 | 
3,50 | 
4,00 | 
4,50 | 
5,00 | 
5,50 | 
6,00 | 
|---|
| 50 | ACCIAIO | 0,6 + 0,5 | 171 | 97 | 60 | 40 | 28 | 20 | 15 | 12 | 9 | 
| 60 | ACCIAIO | 0,6 + 0,5 | 216 | 125 | 79 | 53 | 37 | 27 | 20 | 15 | 12 | 
| 80 | ACCIAIO | 0,6 + 0,5 | 281 | 213 | 193 | 135 | 99 | 75 | 59 | 47 | 38 | 
| 100 | ACCIAIO | 0,6 + 0,5 | 326 | 252 | 205 | 173 | 148 | 113 | 89 | 71 | 59 | 
| 120 | ACCIAIO | 0,6 + 0,5 | 359 | 277 | 225 | 189 | 164 | 137 | 108 | 87 | 61 | 
| 150 | ACCIAIO | 0,6 + 0,5 | 370 | 288 | 239 | 203 | 175 | 149 | 120 | 93 | 64 | 
| 200 | ACCIAIO | 0,6 + 0,5 | 378 | 296 | 250 | 215 | 186 | 155 | 133 | 105 | 78 |