PRODUCTS

    ISOMETAL STAR

    Dimensions

    width mm 1000

    length upon request from continuous production process.

    Thicknesses (S)

    mm 40 - 60 panels of non standard thicknesses can be supplied upon request previous agreement on minimum quantities.

    Supports

    galvanized steel, galvanized prepainted or plastified steel; stainless steel; natural or prepainted aluminium; copper (CORAM).

    Insulation through continuous foaming process

    Polyurethane resins (PUR) and (not standard) polyisocianurate foams (PIR), density 39 ±2 Kg/m³ Declared value of thermal transmittance for a panel after 25 years of its installation, (Appendix C - EN 13165) Initial value of thermal conductivity: λ = 0.020 W/(mK)

    Protective treatments for external support available

    On request for external polyester coating, atoxic prepainted for food contact, silicone polyester, PVDF, thermoplastic Class A application of PVC plastic films or other films.

    EPD certification (CAM)

    CAM available.
    For more information on CAM certification, contact the technical / commercial department.

    Insights PIR foam

    On request is available in PIR foam version (polyisocyanurate), a particular polymeric structure that guarantees excellent characteristics of fire behavior. The entire range of ISOMETAL panels has been certified in Class B-s2, d0 in compliance with UNI EN 13823 (SBI) * where, "B" expresses the quantity of heat produced during the first 600 seconds of the test <7.5 MJ (best value obtainable for foamed products); "S2" represents a very low development of the fumes and "d0" indicates the absolute absence of drops and/or inflamed particles. In last years, the SBI test has become a standard requirement in Europe for fire behavior of building materials. The new European standard for sandwich panels - UNI EN 14509 - uses the SBI system for fire classification purposes. ISOMETAL is the only one in Italy to design light, highly insulating applications with unequaled fire reaction requirements. In many cases it can replace the rock wool panel considering its fire reaction characteristics combined with the very high thermal insulation power.

    LOADS TABLE

    PITCH BETWEEN SUPP.(m)
    PANEL TICKNESS(mm)
    SHEET TICKNESS(mm)
    MATERIAL
    MAXIMUM UNIFORMLY DISTRIBUTED LOAD (daN/m2) - DEFLECTION *
    Panel
    Thickness
    (mm)
    MaterialSheet
    thickness
    (mm)
    Pitch 'L' in meters between the supports
    1,50 2,00 2,50 3,00 3,50 4,00 4,50 5,00 5,50 6,00
    40ALLUMINIO0,5 + 0,4
    40ACCIAIO0,5 + 0,4 236 133 85 59 43 33 26 21 18 14
    60ALLUMINIO0,5 + 0,4
    60ACCIAIO0,5 + 0,4 355 200 128 86 65 50 39 32 26 22
    MAXIMUM UNIFORMLY DISTRIBUTED LOAD (daN/m2) - DEFLECTION *
    Panel
    Thickness
    (mm)
    MaterialSheet
    thickness
    (mm)
    Pitch 'L' in meters between the supports
    1,50 2,00 2,50 3,00 3,50 4,00 4,50 5,00 5,50 6,00
    40ALLUMINIO0,5 + 0,4
    40ACCIAIO0,5 + 0,42371136845332720161311
    60ALLUMINIO0,5 + 0,4
    60ACCIAIO0,5 + 0,432219210872503831252117