PRODUCTS

    ISOWALL

    Dimensions

    width mm 1000

    length upon request from continuous production process.

    Thicknesses (S)

    mm 30 - 40 - 50 - 80 - 100 - 120 panels of non standard thicknesses can be supplied upon request previous agreement on minimum quantities (max. mm 200).

    Supports

    galvanized steel, galvanized prepainted or plastified steel; stainless steel; natural or prepainted aluminium; copper (CORAM).

    Insulation through continuous foaming process

    Polyurethane resins (PUR) and (not standard) polyisocianurate foams (PIR), density 39 ±2 Kg/m³ Declared value of thermal transmittance for a panel after 25 years of its installation, (Appendix C - EN 13165) Initial value of thermal conductivity: λ = 0.020 W/(mK)

    Protective treatments for external support available

    On request for external polyester coating, atoxic prepainted for food contact, silicone polyester, PVDF, thermoplastic Class A application of PVC plastic films or other films.

    EPD certification (CAM)

    CAM available.
    For more information on CAM certification, contact the technical / commercial department.

    Insights PIR foam

    On request is available in PIR foam version (polyisocyanurate), a particular polymeric structure that guarantees excellent characteristics of fire behavior. The entire range of ISOMETAL panels has been certified in Class B-s2, d0 in compliance with UNI EN 13823 (SBI) * where, "B" expresses the quantity of heat produced during the first 600 seconds of the test <7.5 MJ (best value obtainable for foamed products); "S2" represents a very low development of the fumes and "d0" indicates the absolute absence of drops and/or inflamed particles. In last years, the SBI test has become a standard requirement in Europe for fire behavior of building materials. The new European standard for sandwich panels - UNI EN 14509 - uses the SBI system for fire classification purposes. ISOMETAL is the only one in Italy to design light, highly insulating applications with unequaled fire reaction requirements. In many cases it can replace the rock wool panel considering its fire reaction characteristics combined with the very high thermal insulation power.

    LOADS TABLE

    PITCH BETWEEN SUPP.(m)
    PANEL TICKNESS(mm)
    SHEET TICKNESS(mm)
    MATERIAL
    MAXIMUM UNIFORMLY DISTRIBUTED LOAD (daN/m2) - DEFLECTION *
    Panel
    Thickness
    (mm)
    MaterialSheet
    thickness
    (mm)
    Pitch 'L' in meters between the supports
    1,50 2,00 2,50 3,00 3,50 4,00 4,50 5,00 5,50 6,00
    30ACCIAIO0,4 + 0,4 237 171 103 66 44 31 22 17 13 10
    40ALLUMINIO0,4 + 0,4
    40ACCIAIO0,4 + 0,4 317 238 163 107 74 52 38 29 22 17
    50ALLUMINIO0,4 + 0,4
    50ACCIAIO0,4 + 0,4 397 298 230 154 108 77 57 43 34 26
    80ALLUMINIO0,4 + 0,4
    80ACCIAIO0,4 + 0,4 637 478 382 292 214 164 130 101 79 63
    100ALLUMINIO0,4 + 0,4
    100ACCIAIO0,4 + 0,4 709 531 425 354 268 205 162 131 109 91
    120ALLUMINIO0,4 + 0,4
    120ACCIAIO0,4 + 0,4 851 638 510 425 322 246 195 158 130 109
    MAXIMUM UNIFORMLY DISTRIBUTED LOAD (daN/m2) - DEFLECTION *
    Panel
    Thickness
    (mm)
    MaterialSheet
    thickness
    (mm)
    Pitch 'L' in meters between the supports
    1,50 2,00 2,50 3,00 3,50 4,00 4,50 5,00 5,50 6,00
    30ACCIAIO0,4 + 0,420415112096684937282217
    40ALLUMINIO0,4 + 0,4
    40ACCIAIO0,4 + 0,42752031611341088060473629
    50ALLUMINIO0,4 + 0,4
    50ACCIAIO0,4 + 0,434625520216814311387685443
    80ALLUMINIO0,4 + 0,4
    80ACCIAIO0,4 + 0,45654153282712311851841169579
    100ALLUMINIO0,4 + 0,4
    100ACCIAIO0,4 + 0,4634465367303258225183146120100
    120ALLUMINIO0,4 + 0,4
    120ACCIAIO0,4 + 0,4767562442365311271223178145121