ISOROOF 4G
                            
                             
	
	Dimensions
	width mm 1000
	length upon request from continuous production process.
	Thicknesses (S)
	mm 30 - 40 - 50 panels of non standard thicknesses can be supplied upon request previous agreement on minimum quantities.
	External support
	galvanized steel, galvanized prepainted or plastified steel; stainless steel; natural or prepainted aluminium; copper (CORAM).
	Flexible support
	cylindrical bituminous felt paper; embossed aluminum; fiberglass.
	Insulation through continuous foaming process
	Polyurethane resins (PUR) and (not standard) polyisocianurate foams (PIR), density 39 ±2 Kg/m³ Declared value of thermal transmittance for a panel after 25 years of its installation, (Appendix C - EN 13165) Initial value of thermal conductivity: λ = 0.020 W/(mK)
	Protective treatments for external support available
	On request for external polyester coating, atoxic prepainted for food contact, silicone polyester, PVDF, thermoplastic Class A application of PVC plastic films or other films
	CORAM version
	Also available in CORAM version, with copper support (A).
	AGRI version
	Also available in AGRI version, with a flexible support in embossed aluminum.
	Fiberglass version
	Suitable for environments where the presence of aggressive chemical substances affect the standard coating - the support of glass fibers reinforced by the polyester resin guarantee a robust protection against acid vapors and chemical agents.
                             
                                
                             
                             
                             
                                 LOADS TABLE
                             
                                 
                                     PITCH BETWEEN SUPP.(m)
                                 PANEL TICKNESS(mm)
                                 SHEET TICKNESS(mm)
                                 MATERIAL
                                  
                                 
                                     
                                  | MAXIMUM UNIFORMLY DISTRIBUTED LOAD (daN/m2) - DEFLECTION * | 
|---|
Panel  Thickness (mm) | Material | Sheet  thickness (mm) | Pitch 'L' in meters between the supports | 
|---|
  | 
| 1,00 | 
1,50 | 
2,00 | 
2,50 | 
|---|
| 30 | ACCIAIO | 0,5 | 441 | 216 | 124 | 79 | 
| 30 | ACCIAIO | 0,6 | 576 | 257 | 145 | 79 | 
| 30 | ACCIAIO | 0,8 | 765 | 341 | 196 | 125 | 
| 30 | ACCIAIO | 1,0 | 953 | 425 | 242 | 156 | 
| 40 | ACCIAIO | 0,5 | 441 | 216 | 124 | 79 | 
| 40 | ACCIAIO | 0,6 | 576 | 257 | 145 | 79 | 
| 40 | ACCIAIO | 0,8 | 765 | 341 | 196 | 125 | 
| 40 | ACCIAIO | 1,0 | 953 | 425 | 242 | 156 | 
| 50 | ACCIAIO | 0,5 | 441 | 216 | 124 | 79 | 
| 50 | ACCIAIO | 0,6 | 576 | 257 | 145 | 79 | 
| 50 | ACCIAIO | 0,8 | 765 | 341 | 196 | 125 | 
| 50 | ACCIAIO | 1,0 | 953 | 425 | 242 | 156 |